Performance ranges
  • Unit coolers capacity: from 1,05 to 57,0 kW *
  • Airflow: from 650 to 28320 m3/h
  • Brine coolers and CO2 coolers: customized on demand
Coil features
  • High heat exchange efficiency
  • Designed with special profile aluminium fins and inner grooved copper tubes

According to the room temperature, the employed fin spacing is the following:

  • CTE H3 for high temperatures (>= +2 °C): 3,5 mm
  • CTE E4 - A4 for high temperatures (>= +2 °C): 4,0 mm 
  • CTE M6 - E6 - A6 for medium temperatures (>= -15 °C): 6,0 mm (electric defrost version ED is recommended)
  • CTE L8 - E8 - A8 for low temperatures (>= -35 °C): 8,5 mm, only equipped with electric defrost (ED)
Standard defrost

Electric (ED) 400V/3/50Hz

Casing features

Made of a magnesium aluminium alloy, with a smooth finish covered by a plastic protection film
Fan motor features
  1. 250 mm diameter
    - Single-phase, with shaded poles
    - Voltage: 230V/1/50 Hz
    - Protection grade: IP 44
    - Working temperature: +40 °C
    - Inner thermal contact protection
  2. 315 mm diameter
    - Single-phase, with external rotor and inner capacitor
    - Voltage: 230V/1/50-60 Hz
    - Protection grade: IP 44
    - Working temperature: +40 °C
    - Inner thermal contact protection
  3. 350 mm diameter
    - Single-phase, with external rotor and inner capacitor
    - Voltage: 230V/1/50-60 Hz
    - Protection grade: IP 44
    - Working temperature: +40 °C
    - Inner thermal contact protection
  4. 500 mm diameter
    - Three-phase, with external rotor
    - Voltage: 400V/3/50-60 Hz
    - Protection grade: IP 54
    - Working temperature: +40 °C
    - Inner thermal contact protection
Fan guard features
  1. in 250 mm diameter fan motors: manufactured from fibreglass charged polyamide, according to EN 294 standards
  2. in 315, 350 and 500 mm diameter fan motors: manufactured from epoxy-coated steel, according to EN 294 standards 
Air throw The aeraulic combination grants a considerably high air throw, measured in Luvata’s Technical Lab according to CECOMAF GT6-001 standards
Testing Heat exchangers are supplied clean and tested at a pressure of 30 bars 
Miscellaneous Only CTE500 has no fan motors connected

* Nominal capacity: assessed in practical operating ambient, i.e. wet conditions; R404A refrigerant; air inlet temperature = 0 °C; evap. temperature = -8 °C; ΔT = 8 K.

Luvata Heat Transfer Solutions division

Important Notice

On 30th of November 2016, Luvata Heat Transfer Solutions (HTS) Division was purchased by Modine Manufacturing Company. All information on this page is the property of Modine Manufacturing Company.

For the convenience of customers, these pages will continue to be hosted by Luvata while transition work continues.

These pages will transfer to www.modine.com on 17th March 2017.

Visit www.modine.com for more details.



Copyright © 2017 Luvata. All rights reserved.